close
close
12934 supplicant stopped responding to ise during peap tunnel establishment

12934 supplicant stopped responding to ise during peap tunnel establishment

3 min read 26-02-2025
12934 supplicant stopped responding to ise during peap tunnel establishment

The error "12934 supplicant stopped responding to ISE during PEAP tunnel establishment" is a frustrating problem encountered when configuring Protected Extensible Authentication Protocol (PEAP) tunnels with Identity Services Engine (ISE). This article will guide you through troubleshooting this issue, offering practical solutions and explanations. Understanding the underlying causes is crucial for resolving the problem effectively.

Understanding the Error

The error code 12934 signifies a communication breakdown between the supplicant (the client device attempting to connect) and the ISE server during the PEAP tunnel setup phase. This means the authentication process fails before reaching the actual user credential exchange. Several factors can contribute to this failure.

Common Causes of 12934 Errors

  • Network Connectivity Problems: This is the most frequent culprit. Problems like incorrect IP addressing, firewall rules blocking communication, or network latency can interrupt the crucial handshake between the supplicant and ISE. Ensure your device has a valid IP address, subnet mask, and default gateway.

  • Incorrect ISE Configuration: Misconfigurations on the ISE server itself, such as incorrect certificate settings, authentication policies, or authorization profiles, can prevent successful tunnel establishment. Double-check your ISE setup meticulously.

  • Supplicant Issues: Problems with the supplicant software (on the client device) are another possibility. Outdated supplicant software, incorrect configuration, or conflicts with other network applications can lead to the error. Ensure your supplicant is updated and correctly configured.

  • Certificate Problems: PEAP relies heavily on certificates for secure communication. Expired, incorrectly installed, or mismatched certificates on either the ISE server or the client can disrupt the process. Verify certificate validity and correct configuration on both ends.

  • Firewall Interference: Firewalls on either the client device or the network infrastructure can block the necessary ports and protocols for PEAP authentication. Check your firewall rules to ensure that the required ports are open.

Troubleshooting Steps

Let's tackle resolving the "12934 supplicant stopped responding" error systematically:

1. Verify Network Connectivity

  • Ping the ISE Server: From the client device, ping the ISE server's IP address. Successful ping indicates basic network connectivity.

  • Check IP Configuration: Ensure the client device has a valid IP address, subnet mask, and default gateway. Incorrect settings prevent communication.

  • Inspect Network Cables: Ensure all network cables are securely connected and functioning correctly.

2. Examine ISE Server Configuration

  • Check Certificates: Verify that the server certificates are valid and properly installed on the ISE server. Expired or incorrectly configured certificates are common causes of failure.

  • Review Authentication Policies: Examine your ISE authentication policies to ensure they are correctly configured for PEAP authentication and that the right profiles are assigned.

  • Inspect Authorization Profiles: Make sure the authorization profiles allow the necessary network access for authenticated users.

3. Investigate Supplicant Configuration

  • Update Supplicant: Update the supplicant software on the client device to the latest version. Outdated supplicants can have compatibility issues.

  • Check Supplicant Logs: Review the supplicant logs for any detailed error messages that may pinpoint the exact cause of the failure.

  • Restart the Supplicant: Sometimes, a simple restart of the supplicant service can resolve temporary glitches.

4. Address Firewall Issues

  • Check Client Firewall: Ensure that the client device's firewall allows communication on the ports used by PEAP (typically TCP ports 80 and 443).

  • Examine Network Firewall: Inspect any network firewalls to ensure they are not blocking PEAP traffic. Pay attention to both inbound and outbound rules.

5. Troubleshooting Certificate Issues (Advanced)

  • Certificate Renewal: If certificates are expired, renew them immediately.

  • Certificate Validation: Use a certificate validator tool to check the validity and trust chain of the certificates involved.

  • Re-install Certificates: As a last resort, try reinstalling the certificates on both the ISE server and the client device.

Prevention and Best Practices

  • Regular Maintenance: Regularly update your ISE server and supplicant software to benefit from bug fixes and security improvements.

  • Proactive Monitoring: Implement network monitoring tools to proactively detect network problems before they cause authentication failures.

  • Detailed Logging: Enable comprehensive logging on both the ISE server and the client device to facilitate troubleshooting.

By systematically working through these steps, you should be able to identify and resolve the "12934 supplicant stopped responding" error and establish a stable PEAP tunnel. Remember to consult the official documentation for your specific ISE and supplicant versions for detailed configuration instructions.